• 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable
  • 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable
  • 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable
  • 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable

12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable

The MPO connector is a type of fiber connecter. MPO (Multi-Fiber Push On) is a multi-core fiber connecter type. The MPO high -density fiber pre -connection system is currently mainly used in the application of high -density environments of data centers, the application of optical fiber to the building, and the internal connection applications inside the optical transceiver equipment such as the optical device, 40G, 100G, QSFP+.

Premium MPO Fiber Cable | High density & low loss
Reliable quality, full testing, custom specs & OEM available
Professional technical support and global after-sales service

● Product origin: China

● Delivery time: 7 -10 workdays

We are the manufacturer that could support you with good quality at an aggressive price. We are the best choice for you among many traders and resellers. Feel free to send us any of your questions and inquiries, we would be more than pleased to send you more information.

  • 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable
  • 12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable

Description

12F MPO(male) -LC Fan-out 0.9mm 30-35cm Patch cable

Key attributes

Spec items. Single mode (APC 8-degree polished) Multimode (PC Flat polish)
Insertion loss (MPO)
(IEC 61300-3-34)
Standard loss: ≤0.75dB(max), ≤0.50dB(Typical)
Super Low loss: ≤0.35dB(max), ≤0.20dB(Typical)
Standard loss: ≤0.6dB(max), ≤0.50(Typical)
Super Low loss: ≤0.35dB(max), ≤0.20dB(Typical)
Insertion loss (LC/SC/FC/ST)
(IEC 61300-3-6)
≤0.3dB ≤0.3dB
Return loss(MPO) ≥60dB (8degree polishing) ≥25dB
Return loss(LC/SC/FC/ST) APC≥60dB; UPC≥50dB ≥35dB
Durability <0.3dB typical change, 200 matings <0.3dB typical change, 200 matings
Interchangeability ≤0.2dB ≤0.2dB
Tensile strength >70N >70N
Insert-pull Test 500times, IL<0.5dB 500times, IL<0.5dB
Operating Temperature (°C) -40 to + 85°C -40 to + 85°C

Description

Key Parameter Interpretation

Insertion Loss: Reflects the power attenuation of the optical signal as it passes through the connector. A lower value indicates better performance.

Both single-mode and multi-mode APC connectors are available in standard loss and ultra-low loss versions. The ultra-low loss version is more suitable for high-density data centers and other scenarios sensitive to signal attenuation.

Standard LC/SC/FC/ST connectors have an insertion loss of ≤0.3dB, meeting industry standards.

Return Loss: Reflects the reflection of the optical signal at the connector end face. A higher value indicates less reflection and better signal stability.

Single-mode APCs with 8° grinding have a return loss ≥60dB, significantly better than the ≥25dB ​​of multi-mode APCs with planar grinding. Therefore, single-mode systems typically use APC grinding to reduce the impact of reflections on the laser.

Available for

• G657A2/B2 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• G657B3 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• OM1 62.5/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• OM2 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• OM3 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• OM4 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000
• OM5 50/125 MPO-LC, MPO-SC,MPO-FC,MPO-SC,MPO-ST,MPO-E2000

FAQ

Q1: In which scenarios are MPO fiber optic cables primarily used?

A1: MPO fiber cables are mainly used in high-density data center cabling, supporting 40G/100G/200G/400G/800G transmission. Common applications include spine-leaf networks, rack-to-rack interconnects, switch-to-panel connections, and backbone cabling.

Q2: What are the common core counts for MPO fiber optic cables?

A2: Common MPO fiber counts include 8F, 12F, 16F, 24F, and 32F. Some deployments also use 48F or 72F. For 400G/800G networks, 16-fiber MPO is becoming increasingly popular.

    Q3: How to choose between 8-core, 12-core, and 16-core MPO?

    A3: 8F: Common for traditional 40G/100G SR4 applications/12F: Often used for trunk cabling or MPO-to-LC breakout/16F: Ideal for 400G/800G SR8/DR8, offering higher fiber utilization

    Q4: What does MPO polarity mean? Why is it important?

    A4: Polarity defines how Tx and Rx fibers align throughout the link. In MPO systems, incorrect polarity can cause link failure or no connectivity.